menu

Search 4,514 docs, articles & videos from the world’s leading Automotive part manufacturers

  

1757 results found for Hella Ireland

...Saab 900 build year 1994 - 1995 with climate control Discharged battery One cause of a complaint for a recurring discharged battery can be a permanently running fan for the interior temperature sensor. The fan should automatically switch off at most, five minutes after the ignition has...

...Saab 900 II Year of manufacture: 1993 - 1998 Speed control for heating-system fan In the above vehicles, a defective fan control unit can result in the passenger compartment fan operating only at the highest speed. If the fan speed can no longer be controlled by the control...

...Saab 9-5 With air-conditioning Noises from the condensed water drain. If a gurgling noise can be heard in the inside of the vehicle, a possible cause could be the air-conditioning water drains. The drains are located under the vehicle, on the right and left side body sill near the front...

...Seat Alhambra, build year 06/2000 Air conditioning functionless, slow loss of refrigerant. If on this vehicle the air conditioning is functionless due to missing refrigerant or a slow refrigerant loss is found, a possible cause could be a leaking filter/drier housing. The filter/ drier...

...Seat Ibiza III (6K1) Model year: 1999 - 2002 With automatic air conditioning Temperature setting - sudden reset to standard values The following fault may occur in the case of the above-mentioned vehicles: After a while, the preset interior temperature returns to the standard setting (22...

...VW Sharan Ford Galaxy Seat Alhambra Low pressure service connector On the above -mentioned vehicles the low pressure service connector is fitted below the right headlight (pic. 1). To use the connection the right indicator lamp must be removed. A Torx -screw (pic.2) must...

...Skoda Fabia (6Y) Model year: from 1999 Air conditioning causes noises If, in the case of the above-mentioned vehicles, “buzzing noises” occur when the air conditioning is in operation, the cause could well be the expansion valve, rather than the compressor. The noises occur only unde...

...Skoda Fabia (6Y) Model year: from 1999 Engine: all With air-conditioning system Heating/Air-conditioning control Vehicle overheats sporadically In the case of the above-mentioned vehicles, it may be that the pre-selected interior temperature suddenly changes or, when the tempera...

...Smart 451 (Pure and Passion models) Model year: 8/31/2010 - 6/2/2014 Short circuit in coolant shutoff valve The above vehicles can experience a short circuit in the coolant shutoff valve of the heating system due to the effects of wear. The job of the valve is to allow the cold e...

...Subaru Failure of the electronic evaporator thermostat On some Subaru vehicle types a faulty electronic evaporator thermostat with built-on temperature sensor leads to a freezing of the evaporator. This can be notice by measuring the air outlet temperature at the interior centre vent. I...



...[Previous 10 pages] ... 142 | 143 | 144 | 145 | 146 | 147 | 148 | 149 | 150 | 151 ...[Next 10 of 176 pages] ...