menu

Search 4,511 docs, articles & videos from the world’s leading Automotive part manufacturers

  

1757 results found for Hella Ireland

...BMW 3 Series (E 36) All models with 4-cylinder petrol engine Noises from the area of the air conditioning compressor. If there are complaints with these vehicles in relation to the noises from the area of t he air conditioning system compressor, one possible cause is the tensioner pulle...

...Opel Vectra B With 1.8 l and 2.0 l engines (X18XE, X20XEV) Poor engine running and illumination of the engine warning light. If there are complaints with these vehicles about poor engine running, illumination of the engine warning light, and fault code P0100, the following faults could...

...VW Passat Type: 3B2 / 3B5 Model year: up to 03/1998 Coolant temperature warning light flashes In the case of the above-mentioned vehicles, the formation of a coating on the sensor pins of the coolant level sensor can give rise to the coolant temperature warning light flashing even thou...

...Alfa Romeo 166, model year 1998-2001 all models with Bosch Motronic M1.5.5 Poor idling behaviour If there are complaints about the above-mentioned fault, the cause could be deposits in the throttle-valve housing. Due to the deposits, the throttle valve no longer closes correctly. In...

...Ford Explorer, model year 1993-1994 Rough engine running If there are complaints about the above-mentioned fault, the cause may be a loose connector on the ignition control unit. Due to this connector, moisture can penetrate the inside of the connector. A repair kit is available for th...

...Audi A3, model year 1997-2003 Poor starting behaviour If there are complaints about the above-mentioned fault, there could be several causes. Implausible values result in the above-mentioned fault. In addition, the following fault codes may be stored: - 16500 – Coolant temperature...

...Ford Scorpio, model year 09.1994-09.1995 With semi-automatic air conditioning Blower motor occasionally fails If there are complaints about the above-mentioned fault, the cause could be a faulty blower motor resistor. This occurs due to overheating of the resist or heat sink, and with t...

...Opel Vectra C and Signum Model year 2004 Starter not working If there are complaints about the above-mentioned fault, the cause could be a defective fuse. A short-circuit between terminal 50 and the heat shield occurs due to an incorrectly fitted cable lug (twisted 180°). Fuse F 2 the...

...Technical Information Fogging of combination rear lamps Cover lenses of combination rear lamps fogged If there are complaints about the above-mentioned issue, it does not necessarily mean that there is a fault. In the event of a fogged cover lens, the light exit field should dry out w...

...VW Polo Type: 6N1 / 6NF Model year: 1994 Interior blower not working If the blower motor fails on the above-mentioned vehicles, the cause may be a burnt-out ballast resistor. Due to water penetration between the pollen filter insert and the sealing surface of the water channeling, the...



...[Previous 10 pages] ... 49 | 50 | 51 | 52 | 53 | 54 | 55 | 56 | 57 | 58 ...[Next 10 of 176 pages] ...